Finder EU notified body intelligence
1084

RISE Fire Research AS

🇳🇴 Norway · TRONDHEIM Active

www.risefr.no

Designations

CPR Construction products · Regulation (EU) No 305/2011 Active
Designated since2006-04-09
Full scope text from the register
Product families
  • Chimneys, flues and specific products (1/1)
  • Gypsum products (2/4)
  • External thermal insulation composite systems/kits with rendering (ETICS)(1/1)
  • Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1)
  • Thermal insulating products (2/2)
  • Doors, windows, shutters, blinds, gates and related building hardware (1/1)
  • Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1)
  • Wood-based panels (1/2)
  • Wood-based panels (2/2)
  • Internal partition kits (1/5)
  • Internal partition kits (2/5)
  • Space heating appliances (1/2)
Functions
  • Testing Laboratory
  • FPC Certification Body
  • Product Certification Body
  • Inspection Body
Intended use
  • for the construction of external and internal walls subject to fire regulations, in buildings
  • for structural elements in internal or external application
  • for non structural elements in internal or external applications
  • in external wall not subject to fire regulations
  • fire safety
  • fire/smoke compartmentation and on escape routes
  • in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings
  • in buildings
  • in external wall subject to fire regulations
  • for fire compartmentation
  • for uses subject to regulations on reaction to fire
  • for uses subject to reaction to fire requirements
  • for structural elements in internal or external applications
  • chimneys
Standards
  • Building hardware - Controlled door closing devices - Requirement and test methods
  • Building hardware - Door coordinator devices - Requirements and test methods
  • Building hardware - Electrically powered hold-open devices for swing doors - Requirements and test methods
  • Building hardware - Emergency exit devices operated by a lever handle or push pad - Requirements and test methods
  • Building hardware - Panic exit devices operated by a horizontal bar - Requirements and test methods
  • Building hardware - Single-axis hinges - Requirements and tests methods
  • Chimneys - Clay/ceramic flue liners - Requirements and test methods
  • Chimneys - Requirements for metal chimneys - Part 1: System chimney products
  • EN 1125:1997/A1:2001
  • EN 1154:1996/A1:2002
  • EN 1155:1997/A1:2002
  • EN 1158:1997/A1:2002
  • EN 12259-1:1999 + A1:2001
  • EN 12259-2:1999/A1:2001
  • EN 12259-3:2000/A1:2001
  • EN 12259-4:2000/A1:2001
  • EN 12259-5:2002
  • EN 12809:2001
  • EN 12809:2001/A1:2004
  • EN 12815:2001
  • EN 12815:2001/A1:2004
  • EN 12815:2001/A1:2004 Residential cookers fired by solid fuel - Requirements and test methods
  • EN 12859:2001
  • EN 12860:2001
  • EN 13162:2001
  • EN 13163:2001
  • EN 13164:2001
  • EN 13165:2001
  • EN 13166:2001
  • EN 13167:2001
  • EN 13168:2001
  • EN 13169:2001
  • EN 13170:2001
  • EN 13171:2001
  • EN 13229:2001
  • EN 13229:2001/A2:2004
  • EN 13229:2001/A2:2004 Inset appliances including open fires fired by solid fuels - Requirements and test methods
  • EN 13240:2001
  • EN 13240:2001/A2:2004
  • EN 13240:2001/A2:2004 Room heaters fired by solid fuel - Requirements and test methods
  • EN 13986:2002
  • EN 1457:1999/A1:2002
  • EN 179:1997/A1:2001
  • EN 1856-1:2003
  • EN 1935:2002
  • EN 54-12:2002
  • EN 54-5:2000/A1:2002
  • EN 54-7:2000/A1:2002
  • Fire detection and fire alarm systems - Part 12: Smoke detectors - Line detectors - Line detectors using an optical beam
  • Fire detection and fire alarm systems - Part 5: Heat detectors - Point detectors
  • Fire detection and fire alarm systems - Part 7: Smoke detectors - Point detectors using scattered light, transmitted light or ionization
  • Fixed firefighting systems - Components for sprinkler and water spray systems - Part 1: Sprinklers
  • Fixed firefighting systems - Components for sprinkler and water spray systems - Part 2: Wet alarm valve assemblies
  • Fixed firefighting systems - Components for sprinkler and water spray systems - Part 3: Dry alarm valve assemblies
  • Fixed firefighting systems - Components for sprinkler and water spray systems - Part 4: Water motor alarms
  • Fixed firefighting systems - Components for sprinkler and water spray systems - Part 5: Water flow detectors
  • Gypsum based adhesives for gypsum blocks - Definitions, requirements and test methods
  • Gypsum blocks - Definitions, requirements and test methods
  • Inset appliances including open fires fired by solid fuels - Requirements and test methods
  • Residential cookers fired by solid fuel - Requirements and test methods
  • Residential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods
  • Residential independent boilers fired by solid fuel - Nominal heat output up to 50 kW - Requirements and test methods
  • Room heaters fired by solid fuel - Requirements and test methods
  • Thermal insulating products for buildings - Factory made wood fibre (WF) products - Specification
  • Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification
  • Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
  • Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification
  • Thermal insulation products for buildings - Factory made products of expanded perlite (EPB) - Specification
  • Thermal insulation products for buildings - Factory made products of expanded polystyrene (EPS) - Specification
  • Thermal insulation products for buildings - Factory made products of extruded polystyrene foam (XPS) - Specification
  • Thermal insulation products for buildings - Factory made products of phenolic foam (PF) - Specification
  • Thermal insulation products for buildings - Factory made rigid polyurethane foam (PUR) products - Specification
  • Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification
  • Wood-based panels for use in construction - Characteristics, evaluation of conformity and marking
Source: EU Single Market Compliance Space (SMCS), retrieved 2026-06-23.
https://webgate.ec.europa.eu/single-market-compliance-space/notified-bodies/free-search?text=1084

This page is an informational mirror of the official register. It is not affiliated with the European Commission. Always verify the current designation and scope against the official SMCS record before relying on it.