1219
INSTITUTO DE CIENCIAS DE LA CONSTRUCCION EDUARDO TORROJA (IETCC)
Designations
Designated since2026-06-19
Full scope text from the register
Product families
- Reinforcing and prestressing steel for concrete (1/3)
- Reinforcing and prestressing steel for concrete (2/3)
- Roof coverings, rooflights, roof windows and ancillary products (1/6)
- Roof coverings, rooflights, roof windows and ancillary products (2/6)
- Roof coverings, rooflights, roof windows and ancillary products (3/6)
- Roof coverings, rooflights, roof windows and ancillary products (4/6)
- Roof coverings, rooflights, roof windows and ancillary products (5/6)
- Roof coverings, rooflights, roof windows and ancillary products (6/6)
- Structural timber products (1/3)
- Structural timber products (2/3)
- Structural timber products (3/3)
- Fire alarm/detection, fixed fire-fighting, fire and smoke control and explosion suppression products (1/1)
- Aggregates for uses with high safety requirements (2/2)
- Fire stopping, fire sealing and fire protection products (1/2)
- Fire stopping, fire sealing and fire protective products (2/2)
- Structural sealant glazing kits of types (curtain walling)
- Metal anchors for use in concrete (mechanical fasteners)
- Products for ETAs without Guideline (1/2)
- Products for ETAs without Guideline (2/2)
- Expansion joints for road bridges (1/1)
- Six products for European Technical Approvals (Table 1/3)
- Roof coverings, rooflights, roof windows and ancillary products (1/6)
- Roof coverings, rooflights, roof windows and ancillary products (2/6)
- Roof coverings, rooflights, roof windows and ancillary products (3/6)
- Roof coverings, rooflights, roof windows and ancillary products (4/6)
- Roof coverings, rooflights, roof windows and ancillary products (5/6)
- Roof coverings, rooflights, roof windows and ancillary products (6/6)
- Self-supporting translucent roof kits (except glass-based kits) (1/3)
- Self-supporting translucent roof kits (except glass-based kits) (3/3)
- Structural metallic products and ancillaries (1/4)
- Structural metallic products and ancillaries (2/4)
- Structural metallic products and ancillaries (3/4)
- Structural metallic products and ancillaries (4/4)
- Membranes (1/3)
- Membranes (2/3)
- Membranes (3/3)
- Products related to concrete, mortar and grout (1/2)
- Products related to concrete, mortar and grout (2/2)
- Internal and external wall and ceiling finishes (3/5)
- Internal and external wall and ceiling finishes (4/5)
- anchors to attach personal fall protection equipment
- Timber frame and log prefabricated building kits (1/1)
- Wood-based panels (1/2)
- Wood-based panels (2/2)
- Geotextiles (1/2)
- Geotextiles (2/2)
- Thermal insulating products (1/2)
- Thermal insulating products (2/2)
- Doors, windows, shutters, blinds, gates and related building hardware (1/1)
- Seven products for European Technical Approvals (1/2)
- Seven products for European Technical Approvals (2/2)
- Kits for exterior wall claddings (1/2)
- Kits for exterior wall claddings (2/2)
- Liquid applied roof waterproofing kits (3/3)
- Light composite wood-based beams and columns (1/1)
- External thermal insulation composite systems/kits with rendering (ETICS)(1/1)
- Doors, windows, shutters, blinds, gates and related building hardware (1/1)
- Metal anchors for use in concrete for fixing lightweight systems (1/1)
- Ventilation ducts and pipes
- Circulation fixtures (1/2)
- Watertight coverings kits for wetroom floors and walls (1/2)
- Watertight coverings kits for wetroom floors and walls (2/2)
- Liquid-applied bridge deck waterproofing kits
- Cements, building limes and other hydraulic binders
- Chimneys, flues and specific products (1/1)
- Gypsum products (1/4)
- Gypsum products (2/4)
- Gypsum products (3/4)
- Structural bearings (1/1)
- Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1)
- Geotextiles (1/2)
- Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits
- Precast normal/lightweight/autoclaved aerated concrete products (1/1)
- Plastic anchors for use in concrete and masonry (1/1)
- Road construction products (1/2)
- Floorings (2/2)
- Post-tensioning kits for the prestressing of structures (1/1)
- Pins for structural joints (1/2)
- Metal injection anchors for use in masonry (1/1)
- Prefabricated stair kits (1/2)
- Prefabricated stair kits (2/2)
- Masonry and related products (1/3)
- Masonry and related products (3/3)
- Curtain wallings (1/1)
- Pipes, tanks and ancillaries not in contact with water intended for human consumption (1/5)
- Pipes, tanks and ancillaries not in contact with water intended for human consumption (3/5)
- Pipes, tanks and ancillaries not in contact with water intended for human consumption (4/5)
- Pipes, tanks and ancillaries not in contact with water intended for human consumption (5/5)
- Flat glass, profiled glass and glass-block products (1/6)
- Flat glass, profiled glass and glass-block products (2/6)
- Flat glass, profiled glass and glass-block products (3/6)
- Flat glass, profiled glass and glass-block products (4/6)
- Flat glass, profiled glass and glass-block products (5/6)
- Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (1/6)
- Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (3/6)
- Waste water engineering products inside buildings (2/2)
- Waste water engineering products outside buildings (1/3)
- Waste water engineering products outside buildings (2/3)
- Vetures (2/2)
- Internal partition kits (1/5)
- Construction adhesives (1/2)
- Construction adhesives (2/2)
Functions
- Product Certification Body
- FPC Certification Body
- Testing Laboratory
Intended use
- for use in reduntant systems for fixing and/or supporting to concrete elements such as lightweight suspended ceilings, as well as installations
- in installations subject to regulations on energy conservation, used for the transport/ disposal/ storage of water not intended for human consumption, and for heating systems
- as internal or external finishes in walls or ceilings, as relevant, subject to regulations on dangerous substances
- for fire compartmentation and/or fire protection or fire performance
- in buildings
- used for the reinforcement of concrete
- for all use(s) when subject to regulations on reaction to fire
- external wall claddings in ventilated façades (rainscreens) to be fixed to external vertical walls made of masonry (clay, concrete or stone), concrete (cast on site or as prefabricated panels), timber of metal frame in new or existing buildings (retrofit)
- bridges, railtracks and buildings
- in walls, partitions or ceiling (or lining thereof) subject to reaction to fire requirements - used for load bearing applications as system component for drywall constructions (e.g. on wooden based or steel based substructures)
- for fixing and/or supporting concrete structural elements or heavy units such as cladding and suspended ceilings
- to support internal or external wall or ceiling finishes, or suspended ceilings, subject to reaction to fire regulations
- in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements
- for uses contributing to stiffening the roof structure
- for external walls or external finishes of walls
- in walls and partitions subject to reaction to fire regulations
- for uses subject to reaction to fire requirements
- for use as anti-bullet, or anti-explosion glazing
- to be used outside buildings, for rain water, faecal and organic effluents
- for use inside building
- for uses subject to structural performance regulations
- for anchoring uses
- for uses in structural metallic works
- for bridges and buildings
- any
- for internal uses
- for uses subject to reaction to fire regulations
- for internal uses including enclosed public transport premises
- for concrete, mortar and grout
- preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products
- in road bridges
- for uses relating to energy conservation and/or noise reduction
- for bridge decks
- for the prestressing of structures
- for structural repair
- for the construction of external and internal walls not subject to fire regulations, in buildings
- for uses in work's frames
- in installations in areas subject to reaction to fire regulations, used for the transport/disposal/storage of water not intended for human consumption
- in installations in areas subject to resistance to fire regulations, used for the transport/distribution/storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building
- in bridge decks
- for uses subject to regulations on reaction to fire
- for non structural elements in internal or external applications
- for structural uses in concrete, mortar and grout
- additive in the form of bitumen granules for the production of asphalt for roads. The bitumen granules are added in the asphalt production as a partial subsitute for virgin bitumen.
- fire safety
- for circulation area
- to be used in metal structures or in composite metal and concrete structures
- for use in systems, such as facade systems, for fixing or supporting elements which contribute to the stability of the systems
- for uses subject to external fire performance regulations
- as external finishes in walls or ceilings subject to reaction to fire regulations
- for use inside buildings
- in installations subject to regulations on energy conservation, used for the transport/disposal/storage of water not intended for human consumption, and for heating systems
- in installations in areas subject to reaction to fire regulations, used for the transport/ distribution/storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building
- in installations in areas subject to reaction to fire regulations, used for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building
- for use in a glazed assembly intended specifically to provide fire resistance
- as internal or external finishes in walls or ceilings subject to regulations on dangerous substances
- in installations for the transport/distribution/ storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building
- used for the prestressing of concrete
- in buildings and civil engineering works where requirements on individual bearings are critical
- bridges and buildings
- for structural use
- in installations in areas subject to resistance to fire regulations, used for the transport/ distribution/ storage of gas/fuel intende dfor the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building
- for other uses liable to present "safety-in-use" risks and subject to such regulations
- for use as anti-bullet or anti-explosion glazing
- for reinforcing uses
- for stiffening timber-framed windload bearing walls or timber roof struss structures
- in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings
- for structural elements in internal or external applications
- as internal or external finishes in walls or ceilings subject to reaction to fire regulations
- as internal or external finishes in ceilings subject to reaction to fire regulations
- for road construction and surface treatment of roads
- for uses other than those specified in families (1/6), (2/6), (3/6), (4/6), (5/6)
- for uses subject to regulations on dangerous substances
- in walls, columns and partitions
- for use in roofs and roof finishes
- for uses in work's frames and foundations
- fixing and/or supporting to masonry, structural elements (which contribute to the stability of the works) or heavy units such as claddings as well as installations
- for circulation areas
- for surface treatments of roads
- used for construction works and intended to prevent persons from falling from a height or to arrest falls from a height
- to be used in construction works for air ventilation
- for all essential characteristics except for reaction to fire
- for reaction to fire only
- chimneys
- for circulation areas - used to manufacture sign faces for traffic signs according to EN 12899-1. The intended use excludes road-marking as defined in EN 1436
- for structural timber products
- for dwellings and other buildings
- to be used outside buildings, for waste water from buildings and civil engineering works including roads
- in buildings and civil engineering works where requirements on individual beraings are not critical
- for use in masonry walls
- for structural uses
- in buildings, roads and other civil engineering work
- for external walls and roofs
- in external wall not subject to fire regulations
- for the construction of external and internal walls subject to fire regulations, in buildings
- in external wall subject to fire regulations
- as internal finishes in walls or ceilings subject to reaction to fire regulations
- in building works
- for uses subject to resistance to fire regulations (e.g. fire compartmentation)
- in installations in areas subject to reaction to fire regulations, used for the transport/distribution/storage of gas/fuel intended for the supply of building heating/cooling systems, from the external storage reservoir or the last pressure reduction unit of the network to the inlet of the heating/cooling systems of the building
- for structural uses in buildings and other civil engineering works
- fire/smoke compartmentation and on escape routes
- in civil engineering works
- as external walls subject to reaction to fire requirements
- for building works
- for uses contributing to the load-bearing capacity of the structure
- for other uses in buildings and civil engineering works
Standards
- 330046-01-0602
- Acoustic spray coating based on a water-based organic bin
- Additives for asphalt production - bitumen granules made from recycled bituminous roofing felt
- Adhesive backed polymeric films for use on glass in buildings
- Adhesives for wall claddings
- Adjustable concrete screws
- Alkali resistant glass fibres containing zirconium dioxide for use in concrete
- Anchor channels
- Anchor channels (superseding technical specification ‘EAD 330008-02-0601’)
- Anchor channels (superseding technical specification ‘EAD 330008-03-0601’)
- Anchor devices for fastening personal fall protection systems to concrete structures
- Anchor devices for fastening personal fall protection systems to steel or aluminium trapezoidal sheeting substructures
- Anchor devices for fastening personal fall protection systems to timber substructures
- Anchor devices for fastening personal fall protection systems to timber substructures (superseding technical specification ‘EAD 331846-00-0603’)
- Anti-corrosion paint for steel
- Balcony and terrace glazing systems without vertical frames (superseding technical specification ‘EAD 020002-00-0404’)
- Belitic calcium sulphoaluminate and calcium sulphoaluminate based cement (superseding technical specification ‘EAD 150001-00-0301’)
- Blast Furnace Cement CEM III/A with assessment of sulfate resistance (SR) and optional with low effective alkali content (LA) and/or low heat of hydration (LH)
- Blast Furnace Cement CEM III/A with assessment of sulfate resistance (SR) and optional with low effective alkali content (LA) and/or low heat of hydration (LH)’ (superseding technical specification ‘EAD 150009-00-0301’)
- Blended cements with high filler content, ground granulated blast-furnace slag or pozzolanic material or both, and clinker
- Boards made from recycled beverage cartons for use in construction
- Boards made of agglomerated natural cork for thermal and acoustic insulation
- Bonded fastener and bonded expansion fasteners for use in concrete (superseding technical specification ‘EAD 330499-01-0601’)
- Bonded fasteners for use in concrete
- Bonded fasteners for use in concrete (superseding technical specification “ETAG 001-5” and EAD 330499-00-0601)
- Bonded glazing kits and bonding sealants
- Bonded screw fasteners for use in concrete
- Bonded screw fasteners for use in concrete (superseding technical specification ‘EAD 332795-00-0601’)
- Bound polystyrene bulk material for thermal insulation, sound insulation or both (superseding technical specification ‘EAD 040635-00-1201’)
- Building kit based on massive panels with metal frame structure
- CRM (Composite Reinforced Mortar) Systems for strengthening concrete and masonry structures
- Cable nets with fastening components
- Calcined layer silicate based type II addition
- Calcium aluminate based refractory cement
- Calcium carbonate filler aggregate with additional characteristics
- Calcium carbonate fine as active addition with catalytic binding performance for concrete
- Calcium sulphoaluminate based cement
- Cantilever expansion joints for road bridges (superseding technical specification “ETAG 032-6”)
- Cantilevered Structural horizontal glazing (structural glass canopy/roof)
- Caps with intumescent inlay for recessed luminaires in fire-resistant suspended ceilings
- Carbon, glass, basalt and aramid fibre reinforced polymer bars as reinforcement of structural elements
- Cast-in anchor bolts of ribbed reinforcing steel
- Cast-in anchor with internal threaded socket
- Ceiling windows and ceiling daylighting devices
- Cellular glass boards as load bearing layer and thermal insulation outside the waterproofing
- Cement-bonded boards
- Chambers and end caps for surface stormwater detention or retention systems
- Chimney kits with clay or ceramic flue liner with increased adjacent thermal insulation or outer walls jointed by polyurethane-based adhesive, or combination of both
- Clamping kits for connection of precast concrete members (superseding technical specification ‘EAD 332001-00-0602’)
- Clamping system for connection of precast concrete members
- Closure systems for conveyor systems (superseding technical specification ‘EAD 350022-01-1107’)
- Column shoes for structural connections of reinforced concrete columns
- Combined penetration seals for fire dampers
- Composite roof waterproofing kit
- Compound for bitumen and bituminous mixtures made of crumb rubber powder
- Compressed solid earth blocks with or without lime or cement and wall kits made of these blocks and natural hydraulic lime mortar
- Concrete screws for fastening sandwich panels
- Connector for strengthening of existing concrete structures by concrete overlay
- Connector for strengthening of existing concrete structures by concrete overlay: behaviour under seismic action
- Connectors for tubular sections
- Corrosion protection systems with tapes wrapped for metallic load-bearing components
- Corrugated bitumen tiles and sheets
- Couplers for mechanical splices of reinforcing steel bars
- Couplers for mechanical splices of reinforcing steel bars (superseding technical specification ‘EAD 160129-00-0301’)
- Distance-fixing systems for use in concrete and masonry
- Dowels for structural joints under static and quasi-static loading (superseding technical specification ETAG 030)
- Drainage system used in underground rock caverns
- Dry masonry construction system with vertical elements
- EAD 010001-00-0301
- EAD 010003-00-0301
- EAD 010013-00-0301
- EAD 010028-00-0103
- EAD 020002-01-0404
- EAD 030016-00-0402
- EAD 030019-00-0402
- EAD 030065-00-0402
- EAD 030092-00-0605
- EAD 030155-00-0402
- EAD 030218-00-0402
- EAD 030218-01-0402
- EAD 030219-00-0501
- EAD 030271-00-0605
- EAD 030295-00-0605
- EAD 030310-00-0605
- EAD 030350-00-0402
- EAD 030352-00-0503
- EAD 030378-00-0605
- EAD 030400-00-0605
- EAD 030436-00-0503
- EAD 030437-00-0503
- EAD 030588-00-1202
- EAD 030675-00-0107
- EAD 030684-00-0404
- EAD 030927-00-0404
- EAD 040005-00-1201
- EAD 040007-00-1201
- EAD 040010-00-1201
- EAD 040011-00-1201
- EAD 040011-01-1201
- EAD 040012-00-1201
- EAD 040016-00-0404
- EAD 040016-01-0404
- EAD 040036-00-0501
- EAD 040037-00-1201
- EAD 040057-00-1201
- EAD 040057-01-1201
- EAD 040065-00-1201
- EAD 040083-00-0404
- EAD 040083-01-0404
- EAD 040089-00-0404
- EAD 040090-00-1201
- EAD 040138-01-1201
- EAD 040146-00-1201
- EAD 040179-00-1201
- EAD 040287-00-0404
- EAD 040288-00-1201
- EAD 040313-00-1201
- EAD 040369-00-1201
- EAD 040394-00-1201
- EAD 040419-00-1201
- EAD 040427-00-0404
- EAD 040456-00-1201
- EAD 040461-00-1201
- EAD 040465-00-0404
- EAD 040635-00-1201
- EAD 040635-01-1201
- EAD 040643-00-1201
- EAD 040650-00-1201
- EAD 040685-00-1201
- EAD 040708-00-0402
- EAD 040729-00-1201
- EAD 040759-00-0404
- EAD 040773-00-1201
- EAD 040777-00-1201
- EAD 040831-00-1201
- EAD 040914-01-0404
- EAD 040949-00-1201
- EAD 041094-00-1201
- EAD 041125-00-1201
- EAD 041369-00-1201
- EAD 041389-00-1201
- EAD 041499-00-1201
- EAD 041669-00-1201
- EAD 041827-00-0401
- EAD 041877-00-0301
- EAD 042051-00-0502
- EAD 042232-00-0503
- EAD 042461-00-1201
- EAD 050001-00-0301
- EAD 050001-01-0301
- EAD 050003-00-0301
- EAD 050004-00-0301
- EAD 050004-01-0301
- EAD 050009-00-0301
- EAD 050009-01-0301
- EAD 050013-00-0301
- EAD 050019-00-0301
- EAD 060015-00-0802
- EAD 070001-00-0504
- EAD 070001-01-0504
- EAD 070001-02-0504
- EAD 070002-00-0505
- EAD 080001-00-0403
- EAD 080007-00-0101
- EAD 080009-00-0301
- EAD 080013-00-0102
- EAD 090010-00-0404
- EAD 090020-00-0404
- EAD 090034-00-0404
- EAD 090034-01-0404
- EAD 090035-00-0404
- EAD 090058-00-0404
- EAD 090062-00-0404
- EAD 090062-01-0404-v01
- EAD 090074-00-0504
- EAD 090142-00-0404
- EAD 090232-00-0404
- EAD 090240-00-0404
- EAD 100002-00-1106
- EAD 100005-00-1106
- EAD 100012-00-1106
- EAD 100031-00-1103
- EAD 120001-01-0106
- EAD 120011-01-0107
- EAD 120017-00-0106
- EAD 120093-00-0107
- EAD 120109-00-0107
- EAD 120110-00-0107
- EAD 120111-00-0107
- EAD 120112-00-0107
- EAD 120113-00-0107
- EAD 130006-00-0304
- EAD 130010-01-0304
- EAD 130018-00-0303
- EAD 130031-00-0304
- EAD 130087-00-0204
- EAD 130089-00-0304
- EAD 130089-01-0304
- EAD 130191-00-0304
- EAD 130196-00-304
- EAD 130320-00-0304
- EAD 130337-00-0304
- EAD 130348-00-0304
- EAD 130484-00-0304
- EAD 130647-00-0304
- EAD 130661-00-0304
- EAD 130740-00-0304
- EAD 130767-00-0603
- EAD 140015-00-0304
- EAD 140022-00-0304
- EAD 150001-00-0301
- EAD 150001-01-0301
- EAD 150002-00-0301
- EAD 150003-00-0301
- EAD 150004-00-0301
- EAD 150007-00-0301
- EAD 150007-01-0301
- EAD 150008-00-0301
- EAD 150009-00-0301
- EAD 150009-01-0301
- EAD 150035-00-0301
- EAD 150036-00-0301
- EAD 150052-00-0301
- EAD 150080-00-0301
- EAD 160004-00-0301
- EAD 160011-00-0301
- EAD 160012-00-0301
- EAD 160015-00-0102
- EAD 160027-00-0301
- EAD 160031-00-0301
- EAD 160055-00-0301
- EAD 160057-00-0301
- EAD 160071-00-0102
- EAD 160086-00-0301
- EAD 160086-01-0301
- EAD 160088-00-0102
- EAD 160124-00-0301
- EAD 160129-00-0301
- EAD 160129-01-0301
- EAD 160202-00-0301
- EAD 160208-00-0301
- EAD 170005-00-0305
- EAD 170010-00-0305
- EAD 170011-00-0305
- EAD 170018-00-0305
- EAD 170051-00-0305
- EAD 180017-00-0704
- EAD 180041-00-0704
- EAD 190010-00-0502
- EAD 190013-00-0502
- EAD 190022-00-0503
- EAD 190026-00-0502
- EAD 200006-00-0302
- EAD 200014-00-0103
- EAD 200014-01-0103
- EAD 200035-00-0302
- EAD 200036-00-0103
- EAD 200039-00-0102
- EAD 200043-01-0103
- EAD 200050-01-0102
- EAD 200050-02-0102
- EAD 200059-00-0302
- EAD 200077-00-0103
- EAD 200089-00-0302
- EAD 200102-00-0302
- EAD 200112-00-0301
- EAD 200116-00-0302
- EAD 200126-00-0302
- EAD 200188-00-1202
- EAD 200207-00-0302
- EAD 200345-00-0103
- EAD 200379-00-0602
- EAD 210004-00-0805
- EAD 210020-00-0402
- EAD 210024-00-0504
- EAD 210046-01-1201
- EAD 210058-00-0504-v01
- EAD 210080-00-0505
- EAD 210138-00-0504
- EAD 210195-00-0404
- EAD 220009-00-0401
- EAD 220010-00-0402
- EAD 220010-01-0402
- EAD 220020-00-0402
- EAD 220020-01-0402
- EAD 220025-00-0401
- EAD 220034-00-0607
- EAD 220062-00-0401
- EAD 220069-00-0402
- EAD 220078-00-0401
- EAD 220089-00-0401
- EAD 220116-00-0401
- EAD 220122-00-0401
- EAD 220150-00-0401
- EAD 220163-00-0401
- EAD 220169-00-0402
- EAD 230011-00-0106
- EAD 230011-00-0106-v01
- EAD 230012-00-0105
- EAD 230012-01-0105
- EAD 230064-00-0106
- EAD 230145-00-0105
- EAD 230145-00-0105-v01
- EAD 230158-00-0101
- EAD 230328-00-0108
- EAD 250005-00-0606
- EAD 260001-00-0303
- EAD 260002-00-0301
- EAD 260006-00-0301
- EAD 260007-00-0301
- EAD 260009-00-0301
- EAD 260010-00-0301
- EAD 260014-00-0301
- EAD 260017-00-0301
- EAD 260020-00-0301
- EAD 260023-00-0301
- EAD 260024-00-0301
- EAD 260026-00-0301
- EAD 260035-00-0301
- EAD 260048-00-0301
- EAD 260054-00-0301
- EAD 260057-00-0303
- EAD 260067-00-0301
- EAD 280016-00-0602
- EAD 280017-00-0109
- EAD 280050-00-0605
- EAD 300008-00-0404
- EAD 300021-00-0404
- EAD 300031-00-0404
- EAD 330001-00-0602
- EAD 330008-02-0601
- EAD 330008-03-0601
- EAD 330008-04-0601
- EAD 330008-04-0601-v01
- EAD 330008-04-0601-v02
- EAD 330011-00-0601
- EAD 330012-00-0601
- EAD 330014-00-0601
- EAD 330030-00-0601
- EAD 330046-01-0602
- EAD 330046-02-0602
- EAD 330047-01-0602
- EAD 330076-00-0604
- EAD 330076-01-0604-v01
- EAD 330083-02-0601
- EAD 330084-00-0601
- EAD 330087-00-0601
- EAD 330087-01-0601
- EAD 330196-01-0604
- EAD 330232-00-0601
- EAD 330232-01-0601
- EAD 330232-01-0601 -v01
- EAD 330232-02-0601
- EAD 330250-00-0601
- EAD 330250-01-0601
- EAD 330284-00-0604
- EAD 330284-00-0604-v02
- EAD 330424-00-0604
- EAD 330460-00-0604
- EAD 330499-00-0601
- EAD 330499-01-0601
- EAD 330499-02-0601
- EAD 330499-02-0601-v01
- EAD 330747-00-0601
- EAD 330924-00-0601
- EAD 330924-01-0601-v01
- EAD 330965-00-0601
- EAD 331072-00-0601
- EAD 331433-00-0601
- EAD 331531-00-0602
- EAD 331565-00-0602
- EAD 331668-00-0601
- EAD 331846-00-0603
- EAD 331846-01-0603
- EAD 331852-00-0102
- EAD 331985-00-0604
- EAD 332001-00-0602
- EAD 332001-01-0602
- EAD 332229-00-0602
- EAD 332277-00-0601
- EAD 332347-00-0601
- EAD 332347-00-0601-v01
- EAD 332402-00-0601
- EAD 332589-00-0601
- EAD 332589-01-0601
- EAD 332699-00-0601
- EAD 332700-00-0601
- EAD 332707-00-0602
- EAD 332795-00-0601
- EAD 332795-01-0601
- EAD 333037-00-0602
- EAD 333220-00-0601
- EAD 333256-00-0603
- EAD 333530-00-0601
- EAD 333915-00-0601
- EAD 334812-00-0602
- EAD 340002-00-0204
- EAD 340006-00-0506
- EAD 340020-00-0106
- EAD 340024-00-0103
- EAD 340025-00-0403
- EAD 340037-00-0204
- EAD 340059-00-0106
- EAD 340109-00-0106
- EAD 340179-00-0203
- EAD 340210-00-0104
- EAD 340225-00-1109
- EAD 340275-00-0104
- EAD 340282-00-0303
- EAD 340287-00-0203
- EAD 340292-00-0303
- EAD 340297-00-0203
- EAD 340308-00-0203
- EAD 340309-00-0305
- EAD 340309-00-0305-v01
- EAD 340351-00-0104
- EAD 340352-00-0104
- EAD 340376-00-0111
- EAD 340383-00-0203
- EAD 340392-00-0104
- EAD 340451-00-0104
- EAD 340452-00-0204
- EAD 340503-00-1106
- EAD 340549-00-0204
- EAD 340739-00-0106
- EAD 350003-00-1109
- EAD 350005-00-1104
- EAD 350022-00-1107
- EAD 350022-02-1107
- EAD 350134-00-1104
- EAD 350140-00-1106
- EAD 350141-00-1106
- EAD 350142-00-1106
- EAD 350402-00-1106
- EAD 350454-00-1104
- EAD 350454-00-1104-v01
- EAD 350865-00-1106
- EAD 351141-00-1104
- EAD 351281-00-1104
- EAD 360001-00-0803
- EAD 360001-01-0803
- EAD 360001-02-0803
- EAD 360027-00-0101
- EAD 360032-00-0803
- ETICS with renderings on mono-layer or multi-layer wall made of timber
- Early Suppression, Fast Response (ESFR), K240 to 480, Upright and Pendent Automatic Fire Sprinkler
- Earthquake-resistant kits composed of steel-concrete composite beams, columns and beam-column joints
- Elastic micro hollow spheres as concrete admixture
- Expanded polystyrene foam boards as load bearing layer and thermal insulation outside the waterproofing
- Expanding Structural Bolting Assemblies for Blind Fastening
- External Thermal Insulation Composite Systems (ETICS) with renderings (superseding technical specification “ETAG 004”)
- External Thermal Insulation Composite Systems with renderings for the use on timber frame buildings
- External thermal insulation composite system (ETICS) with rendering on boards based on polystyrene and cement
- External thermal insulation composite systems with rendering system (superseding technical specification ‘EAD 040083-00-0404’)
- Externally-bonded composite systems with inorganic matrix for strengthening of concrete and masonry structures
- Extruded polystyrene foam boards as load bearing layer and/or thermal insulation outside the waterproofing
- Factory made cellular glass loose fill
- Factory made self-supporting composite PUR/PIR foam insulated metal sheet for roofing, external cladding and internal lining
- Factory-made boards and products formed by moulding of an expanded polylactic acid (E-PLA) for thermal and/ or acoustical insulation
- Factory-made bonded foam to be used as acoustic and thermal insulation
- Factory-made insulation mats made of glass fibres and amorphous silica
- Factory-made products of extruded, foamed polyethylene terephthalate for thermal insulation’
- Factory-made thermal and acoustic insulations made of polyester fibres
- Factory-made thermal and/or acoustic insulation products made of vegetable or anymal fibres
- Falling rock protection kits.
- Fastener for push-pull props for precast wall/column elements
- Fastener of external wall claddings
- Fasteners for fixing external thermal insulation composite systems on timber constructions
- Fastening screws for fastening metal members and sheeting to metal or timber structures (superseding technical specification ‘EAD 330046-01-0602’)
- Fastening screws for sandwich panels
- Fastening screws with welded or cold-formed set screws
- Fiber reinforced silica aerogel thermal insulation
- Fiber ropes with end connectors
- Fibre-reinforced polymer kits made of a carbon or glass fabric and an epoxy resin
- Fibre-reinforced polymer kits made of a pultruded carbon fibre laminate and an epoxy adhesive
- Fibres for concrete – steel fibres recovered from end-of-life tyres
- Fire proof water trap with intumescent fire seal (combined with a stainless steel floor gully penetration)
- Fire protective board, slab and mat products and kits
- Fire retardant products (superseding technical specification “ETAG 028”)’
- Fire stopping and fire sealing products - Penetration seals
- Fire-resistant reactive air transfer grilles
- Fixed fire-resistant roof window
- Flashings for daylight devices
- Flat and profiled (with a pattern) plastic roofing sheets made of recycled material for fully supported discontinuous roofing
- Flat plastic roofing sheets made of recycled plastic for self-supporting and/or fully supported discontinuous roofing and/or external cladding
- Flat plastic sheets for fully supported discontinuous roofing and external cladding
- Flexible asphaltic plug expansion joints for road bridges (superseding technical specification “ETAG 032-3”)
- Flexible avalanche protection kit
- Flexible interlayer for the reduction of flanking sound and vibration transmission
- Flexible kits for retaining debris flows and shallow landslides/open slope debris flows
- Flexible plug expansion joints for road bridges with flexible filling based on a synthetic polymer as binder (superseding technical specification ‘EAD 120011-00-0107’)
- Flexible polymer modified mineral thick coatings
- Flexible sprinkler hose with end fittings
- Fluoraluminate rapid setting cement
- Full-bodied sintered stone slabs for use in claddings, floorings, pavings, stairs, rainscreens and curtain walling kits
- Fully bonded, pre-applied flexible sheet for waterproofing
- Gabion boxes, mattresses and sack gabions made of hexagonal regular twisted mesh metallic pre-coated with or without additional organic coating
- Gabion boxes, mattresses and sack gabions made of hexagonal regular twisted mesh with pre-coated zinc and/or zinc+organic coating.
- Geosynthetic cementitious composite mats and barriers
- Glass fibre joint tape for gypsum plasterboards
- Glass fibre mesh for reinforcement of cement based renderings
- Glass fibre mesh for reinforcement of cementitious or cement-based renderings
- Glass, basalt, aramid, carbon, PBO (polyparaphenylene benzobisoxazole) and steel rovings for fibre-reinforced anchor spikes
- Glass-ceramic panels for external cladding
- Glued laminated timber made of hardwood – Structural laminated veneer lumber made of beech
- Glued laminated timber made of solid hardwood
- Glued laminated timber with full cross section finger joint
- Glued laminated veneer lumber
- Glued-in rods for timber connections
- Glulam strengthened by laminated veneer lumber, glued laminated veneer lumber made of finger-jointed laminations and block-glued glulam made thereof
- Gypsum plasterboard for load bearing applications
- Gypsum plasterboards for load bearing applications
- Gypsum plasterboards, gypsum boards with fibrous reinforcement and expanded glass boards with fibrous reinforcement for sheathing and lining of building elements (superseding technical specification ‘EAD 070001-01-0504’)
- Headed reinforcement steel bars
- Hexagonal woven gabion boxes and mattresses with zinc coatings
- High load-bearing and low load-bearing single anchor earth retaining structures made of steel
- High strength cement
- High-strength structural bolting assemblies for hydraulically operated, friction-less and torsion-free tightening
- Humidity-dependent vapour control layers
- Hydrophilic thermal insulation product made of mineral wool for water retention in green roofs and similar applications
- Impact sound insulation mat with additional function of rainwater drainage and protection of external waterproofing layers
- In-situ concrete slab permanent joint former
- In-situ formed loose fill thermal and/or acoustic insulation product made of granulated expanded cork
- In-situ formed loose fill thermal and/or acoustic insulation products made of vegetable fibres
- In-situ formed loose-fill thermal and/or acoustic insulation material made of animal fibres
- In-situ loose fill thermal and/or acoustic insulation products made of vegetable fibres to be used in floor constructions without additional load-bearing structures
- Injected anchor for thermal insulation boards
- Inorganic fibre grids for reinforcement of cement-, anhydrite- or resin-based screeds
- Insulated glass unit with structural sealant punctually anchored
- Insulating boards made of recycled polyurethane to be used as acoustic and thermal insulation
- Insulating building element for masonry walls
- Insulating foils as barrier against substances with relevance to indoor air quality
- Insulation made of loose-fill or compound granulated expanded cork
- Insulation product made of expanded perlite (EPB)
- Intumescent products for fire sealing and fire stopping purposes
- Jointless, ecological flowing screed made of renewable and sustainable raw materials
- Kit composed by subframe and fixings for fastening cladding and external wall elements
- Kit for closure system for conveyor systems (Superseded by 350022-01-1107)
- Kit for fire resistant service ducts consisting of pre-fabricated connection pieces (made of mechanically pre-coated steel sheet) and accessories
- Kit for micropiles — Kit with hollow bars for self-drilling micropiles — Hollow bars of seamless steel tubes
- Kit for reinforced concrete members with high strength reinforcing steel but limited tensile utilisation
- Kit for rock and soil anchors using prestressing steel strand
- Kit of polyurethane elements for thermal insulation frame around windows made of unplasticized polyvinyl chloride profiles
- Kits composed by subframe and fixings for fastening claddings and external wall elements (superseding technical specification ‘EAD 090034-00-0404’)
- Kits for connection of precast concrete façade elements to concrete structures based on anchor channels
- Kits for construction of a micropile – Kits with thread bars
- Kits for construction of a rock and soil anchor – Kits with thread bars of steel or prestressing steel
- Kits for construction of a rock and soil nail – Kits with hollow bars for a self-drilling nail – Hollow bars of seamless or welded steel tubes
- Kits for external thermal insulation composite system (ETICS) with mortar as thermal insulation product and renderings or discontinuous claddings as exterior skin
- Kits for external thermal insulation composite system (ETICS) with panels as thermal insulation product and discontinuous claddings as exterior skin
- Kits for external wall claddings made of agglomerated stone
- Kits for external wall claddings mechanically fixed
- Kits for green roofs
- Kits for green roofs with green roofing elements made of plastic and its fixing devices
- Kits for self-supporting and interconnected ventilated cavity walls
- Kits for the strengthening of concrete elements by externally bonded and near-surface- mounted carbon fibre-reinforced polymer strips (superseding technical specification ‘EAD 160086-00-0301’)
- Kits for the strengthening of concrete elements by externally bonded carbon fibre reinforced polymer strips
- Kits made of alkali-resistant glass fibre mesh, connectors and mortar for strengthening of masonry and reinforced concrete elements by external bonding
- Kits made of insulation boards with protective finishing for inverted roofs
- L- or Z-shaped metal sheets for the increase of punching shear resistance of flat slabs or footings and ground slabs
- Laminated segment timber with rectangular cross section made from radially cut logs
- Lattice girders for the increase of punching resistance in flat slabs and column
- Light weight steel/wood load bearing roof elements
- Lightweight panel made of mortar of cement and granulated EPS reinforced by a glass fibre mesh and an internal steel railing
- Linear joint and gap seals
- Liner, made of glass fibres, mineral and organic substances used for relining of ducts for ventilation purposes
- Liquid applied bridge deck waterproofing kits.
- Liquid applied roof waterproofing kits (superseding technical specification “ETAG 005”)
- Liquid applied roof waterproofing on the basis of polysiloxane
- Liquid applied watertight covering kits for wet room floors and/or walls (superseding technical specification “ETAG 022-1”)
- Load bearing thermal insulating elements which form a thermal break between balconies and internal floors
- Load-bearing external wall and partition wall kit
- Load-bearing sandwich panels with foam or polymeric core and skins of structural cement bonded particle boards
- Load-bearing thermal insulation elements which form a thermal break between balconies and internal floors (superseding technical specification ‘EAD 050001-00-0301’)
- Low bitumen mass shingles, laminated or not, with mineral or synthetic reinforcement
- Low lambda composite boards made of mineral wool fibres and aerogel additives
- Low-bitumen-mass shingles, laminated or not, with mineral or synthetic reinforcement (superseding technical specification ‘EAD 220020-00-0402’)
- Mat expansion joints for road bridges (superseding technical specification “ETAG 032-5”)
- Mechanical fasteners for use in concrete
- Mechanical fasteners for use in concrete (superseding technical specification ‘EAD 330232-00-0601’)
- Mechanical fasteners for use in concrete (superseding technical specification ‘EAD 330232-01-0601’)
- Membrane for use as roof underlay
- Membranes for use as roof or walls underlays or both
- Metal expansion fastener for use in autoclaved aerated concrete
- Metal injection anchors for use in masonry.
- Metal web beams and columns
- Microprismatic retro-reflective sheetings
- Mineral pre-coated ceiling panels
- Minerally-bonded boards made of wood chips
- Modular construction system
- Modular element for building services
- Modular expansion joints for road bridges (superseding technical specification “ETAG 032-8”)
- Modular pre-fabricated cemetery construction structure
- Natural calcined pozzolana as type II addition for concrete
- Natural cork-based mats to be used for thermal and impact sound insulation
- Non load-bearing permanent shuttering kits/systems based on hollow blocks or panels of insulating materials and sometimes concrete (superseding technical specification ‘ETAG 009’)
- Non-flexible mineral sealing slurry kit on the basis of cement
- Non-load-bearing polyvinyl chloride panels for internal and external walls
- Non-screwable sleeve for mechanical splices by lateral compression of reinforcing bars
- Nosing expansion joints for road bridges (superseding technical specification “ETAG 032-4”)
- Open-cell factory-made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products for building equipment and industrial installations
- Panels of steel wires with incorporated thermal insulation for a whole structure
- Permanent insulating shuttering kits for whole buildings
- Pile Joints and Rock shoes for concrete piles
- Pile joint and rock shoe for concrete piles
- Pile pipes made of ductile iron
- Plastic anchors for redundant non-structural systems in concrete and masonry
- Plastic anchors made of virgin or non-virgin material for fixing of external thermal insulation composite systems with rendering
- Plastic chamber systems for underground network access applications installed below manhole tops
- Point fastening kits for roof panels
- Polyethylene terephthalate-based foils with coating for insulating glass units
- Polymer macro fibres reinforced with alkali resistant glass fibre for the use in concrete
- Polymer macro fibres reinforced with basalt fibre for the use in concrete
- Polymeric concrete addition
- Polystyrene concrete masonry units and wall kits made from the units
- Portland cement with pozzolanic filler for tropical use (superseding technical specification ‘150007-00-0301’)
- Portland-pozzolana cement for use in tropical conditions
- Post-installed fasteners in concrete under fatigue cyclic loading
- Post-installed reinforcing bar (rebar) connections with improved bond-splitting behaviour
- Post-tensioning systems for prestressing of structures
- Post–installed fasteners in concrete under fatigue cyclic loading (superseding technical specification ‘EAD 330250-00-0601’)
- Pot bearings with special internal sealing for increased action effects
- Powder actuated fastener for the fixing of ETICS in concrete
- Power-actuated fastener for multiple use in concrete for non-structural applications.
- Pre-assembled drainage panels made of gabions and geotextile
- Pre-installed anchor for fastening concrete façade elements
- Precast balcony elements made of ultra-high performance fibre reinforced concrete (UHPFRC)
- Precast concrete composite wall with point connectors
- Prefabricated fire-resistant building units
- Prefabricated soil and water barrier systems made of polyvinyl chloride
- Prefabricated stair kits
- Prefabricated wood slab element made of jointed cross laminated log elements to be used as a structural element in buildings
- Prefabricated wood-based loadbearing stressed skin panels (superseding technical specification “ETAG 019”)
- Pressure-equalizing insulating glass units
- Processed bottom ash from municipal solid waste incinerators as type II addition for production of concrete, mortar and grout
- Products for installation systems for supporting technical building equipment
- Rapid hardening sulfate resistant calcium sulphoaluminate based cement
- Rapid setting cement
- Re-bend connection
- Re-cycled clay masonry units
- Reactive coatings for fire protection of steel elements
- Rectangular geogrid for the stabilization of unbound granular layers under applied load
- Reinforced high density EPS structural panel system for building units
- Renderings and rendering kits intended for fire resistant applications
- Resettable line-type heat detectors
- Resilient floorings made of ethylene propylene diene-(monomer) and rubber granules
- Retrofit kits for small wastewater treatment plants
- Rigid seismic sway brace for fire sprinkler pipe work
- Road marking products
- Road markings - retro-reflective elements
- Roof and wall systems with hidden fastenings
- Roof tile coupling system
- Roof window with integrated balcony element
- Rooflight with bonded or mechanically fastened cover glass
- Rotationally moulded bunded storage tank made of polyethylene
- Rubber modified bitumen binders
- S-shaped double headed reinforcement elements for the increase of punching shear resistance of footings and ground slabs
- SRP (Steel Reinforced Polymer) kit made of steel micro-wires, fiberglass mesh and epoxy adhesive
- Screw anchors for autoclaved aerated concrete and lightweight aggregate concrete
- Screw anchors for use in masonry
- Self-supporting translucent roof kits with covering made of plastic sheets (superseding technical specification “ETAG 010”)
- Service penetrations for pipes through walls and floors
- Shallow and reusable foundation kit for lightweight structures
- Shrinkage reducing admixture for concrete
- Solid wood boards for flatwise structural use with overlapping edge profiles
- Special block glued laminated timber
- Special cements – Carbonation hardening cements requiring a particular curing process
- Special filling products for post-tensioning kits
- Spherical and cylindrical bearing with special sliding material made of UHMWPE (Ultra high molecular weight poyethylene)
- Spherical and cylindrical bearing with special sliding material made of filled PTFE with solid lubricant and reinforcing fibres
- Spherical and cylindrical bearing with special sliding material made of fluoropolymer
- Spherical and cylindrical bearings with special sliding material made of fluoropolymer (superseding technical specification ‘EAD 050009-00-0301’)
- Spherical and cylindrical bearings with special sliding material made of ultra-high- molecular-weight polyethylene (superseding technical specification ‘EAD 050004-00-0301’)
- Stainless steel point fastener for glass claddings
- Stainless-steel point connectors for sandwich walls
- Steel components for pallet racking systems
- Steel plate with cast-in anchor
- Steel spring elements
- Stone wool elements used for large-scale water storage in civil works
- Structural finger-jointed, wet, cold or wet and cold glued solid timber (superseding technical specification ‘EAD 130089-00-0304’)
- Structural hollow sections of weathering steel
- Structural panelled building kit
- Structural sections made from fibre reinforced polymers (FRP/Glassfiber Composites)
- Structural steel composite wall panels for building systems
- Structural wet and/or cold glued finger jointed solid timber
- Stud connectors for anchoring in reinforced concrete members as well as for connecting steel members with reinforced concrete members
- Substructure kit for heated buildings
- Support fixing assemblies
- Supported expansion joints for road bridges (superseding technical specification “ETAG 032-7”)
- Systems for post-installed rebar connections with mortar
- Systems for post-installed rebar connections with mortar (superseding technical specification ‘EAD 330087-00-0601’)
- Tension proof loaded structural finger jointed solid timber which may be processed to glued laminated timber and glued solid timber
- Thermal and sound insulating dry screed systems with prefabricated flooring elements
- Thermal and/or sound insulation based on bound expanded polystyrene bulk material
- Thermal insulation an/or sound absorbing boards based on expanded polystyrene and cement
- Thermal insulation board made of microporous silica
- Thermal insulation board made of microporous silica (superseding technical specification ‘EAD 040057-00-1201’)
- Thermal insulation board made of pressed rigid polyurethane foam
- Thermal insulation board made of silica- or polyurethane-aerogel on a carrier material
- Thermal insulation elements of fibre-reinforced polymer which form a thermal break between structural elements
- Thermal insulation for buildings made of straw bales
- Thermal insulation made of loose fill mineral wool
- Thermal insulation products for buildings with radiant heat reflective component
- Thermally curved annealed glass and laminated safety glass made of thermally curved annealed glass
- Thermally-insulating and loadbearing units made of cellular glass
- Thin metal composite sheets (superseding technical specification ‘EAD 210046-00-1201’)
- Threaded studs for connection of materials to structural steel and aluminium members
- Three-layer polyethylene-based coating for corrosion protection of steel pipes
- Timber building kits (superseding technical specification “ETAG 007”)
- Torque-controlled expansion fasteners for use in concrete with variable working life up to 50 years
- Type I addition for concrete, mortar and screed materials – Aqueous solution
- Ultra-thin natural stone veneer sheets for internal and external wall finishes and roof coverings
- Underlays made of granulated polyurethane-foam with or without granulated cork
- Vacuum insulating glass units
- Vacuum insulation panels (VIP) with factory applied protection layers
- Vacuum insulation panels with factory-applied protection layers (superseding technical specification ‘EAD 040011-00-1201’)
- Variant: Anchor channels for controlled impact screwdrivers
- Variant: Anchor channels under fatigue cyclic shear with different lower load level
- Variant: Assessment of components for wood-based composite panels not produced by the manufacturers themselves
- Variant: Bonded fasteners and bonded expansion fasteners for use in concrete - Alternative drilling methods, seismic and fire resistance in steel fibre reinforced concrete, variable working life and time-to-failure assessment
- Variant: Cast-in anchor bolts under fatigue or seismic actions
- Variant: Compound for bitumen and bituminous mixtures based on crumb rubber powder – Extension of scope
- Variant: Kits for external wall claddings mechanically fixed – Extension of scope
- Variant: Metal injection anchors for use in masonry - Anchor groups under fire exposure
- Variant: Non-load-bearing permanent shuttering kits or systems based on hollow blocks or panels of insulating materials and sometimes concrete: hollow blocks resistant to seismic actions
- Variant: Plastic anchors for redundant non-structural systems in concrete and masonry, and for fixing façade claddings through angle brackets under seismic actions in concrete and masonry
- Variant: Road marking products – Extension of scope
- Ventilated external wall cladding kit comprising a metallic honeycomb panel and its associated fixings
- Ventilation system made of mineral wool covered with film (outside and inside)
- Ventilation system made of mineral wool with facings on outside and inside (superseding technical specification ‘EAD 360001-00-0803’)
- Ventilation systems made of mineral wool with facings on outside and inside (superseding technical specification ‘EAD 360001-01-0803’)
- Veture kits – prefabricated units for external wall insulation and their fixing devices (superseding technical specification ‘EAD 040914-00-0404’)
- Walls, roofs and ceilings made of OSB-panels which are glued together on their surfaces
- Waterproofing admixture for concrete
- Waterproofing kit based on polymeric membranes for in- and outdoor walls and floors of wet areas and swimming pools
- Watertight covering kits based on flexible sheets for wet room floors and/or walls (superseding technical specification “ETAG 022-2”)
- Watertight covering kits based on inherently watertight boards for wet room floors and/or walls (superseding technical specification “ETAG 022-3”)
- Wedge lock washers for structural bolting assemblies
- White high alumina calcium aluminate cement
- Wire loop system for the connection of precast and in-situ concrete elements
- Wire loop system for the connection of precast and in-situ concrete elements (superseding technical specification ‘EAD 332589-00-0601’)
- Wood and metal lighting columns
- Wood-based composite panel for facades
- Wood-based dowel-type fasteners
- Wood-concrete composite slab kits
- additives for asphalt production - additive from bitumen granules made from recycled bituminous roofing felt
- fasteners for use in concrete for redundant non-structural systems
- geocomposite for drainage system
- one component bituminen-polyurethane resin for flashing application
- spiral cable anchor
- thermal insulation board made of mineral material
- thermal insulation product made of loose fill expanded perlite (EP)
Source: EU Single Market Compliance Space (SMCS), retrieved 2026-06-23.
https://webgate.ec.europa.eu/single-market-compliance-space/notified-bodies/free-search?text=1219
https://webgate.ec.europa.eu/single-market-compliance-space/notified-bodies/free-search?text=1219
This page is an informational mirror of the official register. It is not affiliated with the European Commission. Always verify the current designation and scope against the official SMCS record before relying on it.