2337
Cambridge Fire Research Limited
Designations
Designated since2011-10-11
Full scope text from the register
Product families
- Masonry and related products (2/3)
- Gypsum products (1/4)
- Gypsum products (2/4)
- Gypsum products (3/4)
- Internal and external wall and ceiling finishes (1/5)
- Doors, windows, shutters, blinds, gates and related building hardware (1/1)
- Flat glass, profiled glass and glass-block products (1/6)
- Internal partition kits (1/5)
- Internal partition kits (2/5)
- Timber frame and log prefabricated building kits (1/1)
- Non load bearing permanent shutterings: kits/systems based on hollow blocks or panels of insulating materials and, sometimes, concrete (1/1)
- Prefabricated wood-based load-bearing stressed skin panels and self-supporting composite lightweight panels (2/6)
- Fire stopping, fire sealing and fire protection products (1/2)
- Fire stopping, fire sealing and fire protective products (2/2)
- Metal frame building kits, concrete frame building kits, prefabricated building units, cold storage room kits and rock-fall protection kits
Functions
- Testing Laboratory
Intended use
- for stiffening timber-framed windload bearing walls or timber roof struss structures
- in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings
- for use in a glazed assembly intended specifically to provide fire resistance
- for fire compartmentation and/or fire protection or fire performance
- for uses subject to reaction to fire regulations
- for the construction of external and internal walls subject to fire regulations, in buildings
- for uses subject to reaction to fire requirements
- as internal or external finishes, as complete elements, used for fire protection of walls or ceilings
- in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements
- for uses subject to resistance to fire regulations (eg fire compartmentation)
- in walls and partitions
- fire/smoke compartmentation and on escape routes
- for fire compartmentation
- in building works
- other declared specific uses and/or uses subject to other specific requirements, in particular noise, energy, tightness and safety-in-use (i.e. NOT for fire/smoke compartmentation, NOT for escape routes)
Standards
- Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods
- Building hardware - Controlled door closing devices - Requirement and test methods
- Building hardware - Door coordinator devices - Requirements and test methods
- Building hardware - Electrically powered hold-open devices for swing doors - Requirements and test methods
- Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods
- Building hardware - Locks and latches - Mechanically operated locks, latches and locking plates - Requirements and test methods
- Building hardware - Single-axis hinges - Requirements and tests methods
- EN 1096-4:2004
- EN 1125:2008
- EN 1154:1996/A1:2002
- EN 1154:1996/A1:2002/AC:2006
- EN 1154:1996/A1:2002/AC:2006 Building hardware - Controlled door closing devices - Requirements and test methods
- EN 1155:1996/A1:2002/AC:2006
- EN 1155:1996/A1:2002/AC:2006 Building hardware - Electrically powered hold-open devices for swin doors - Requirements and test methods
- EN 1155:1997/A1:2002
- EN 1158:1997/A1:2002
- EN 1158:1997/A1:2002/AC:2006
- EN 1158:1997/A1:2002/AC:2006 - Building hardware - Door coordinator devices - Requirements and test methods
- EN 12150-2:2004
- EN 12209:2003
- EN 12209:2003/AC:2005
- EN 12209:2003/AC:2005 Building hardware - Locks and latches - Mechanically operated locks, latches and locking plates - Requirements and test methods
- EN 12337-2:2004
- EN 1279-5:2005+A2:2010
- EN 1279-5:2005+A2:2010 Glass in building - Insulating glass units - Part 5: Evaluation of conformity
- EN 12859:2011
- EN 12859:2011 Gypsum blocks - Definitions, requirements and test methods
- EN 13024-2:2004
- EN 13279-1:2008
- EN 13950:2005
- EN 14178-2:2004
- EN 14179-2:2005
- EN 14190:2005
- EN 14321-2:2005
- EN 14351-1:2006+A1:2010
- EN 14449:2005
- EN 14449:2005/AC:2005
- EN 14449:2005/AC:2005 - Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard
- EN 14496:2005
- EN 1748-1-2:2004
- EN 1748-2-2:2004
- EN 179:2008
- EN 1863-2:2004
- EN 1935:2002
- EN 1935:2002/AC:2003
- EN 1935:2002/AC:2003 Building hardware - Single-axis hinges - Requirements and test methods
- EN 438-7:2005
- EN 520:2004+A1:2009
- EN 520:2004+A1:2009 Gypsum plasterboards - Definitions, requirements and test methods
- EN 572-9:2004
- EN 845-2:2003
- Glass in building - Basic alkaline earth silicate glass products - Part 2: Evaluation of conformity/Product standard
- Glass in building - Basic soda lime silicate glass products - Part 9: Evaluation of conformity/Product standard
- Glass in building - Chemically strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard
- Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard
- Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard
- Glass in building - Heat strengthened soda lime silicate glass - Part 2: Evaluation of conformity/Product standard
- Glass in building - Laminated glass and laminated safety glass - Evaluation of conformity/Product standard
- Glass in building - Special basic products - Borosilicate glasses - Part 1-2: Evaluation of conformity/Product standard
- Glass in building - Special basic products - Glass ceramics - Part 2-2: Evaluation of conformity/Product standard
- Glass in building - Thermally toughened alkaline earth silicate safety glass - Part 2: Evaluation of conformity/Product standard
- Glass in building - Thermally toughened borosilicate safety glass - Part 2: Evaluation of conformity/Product standard
- Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard
- Gypsum binders and gypsum plasters - Part 1: Definitions and requirements
- Gypsum based adhesives for thermal/acoustic insulation composite panels and plasterboards - Definitions, requirements and test methods
- Gypsum plasterboard products from reprocessing - Definitions, requirements and test methods
- Gypsum plasterboard thermal/acoustic insulation composite panels - Definitions, requirements and test methods
- High-pressure decorative laminates (HPL) - Sheets based on thermosetting resins (Usually called Laminates) - Part 7: Compact laminate and HPL composite panels for internal and external wall and ceiling finishes
- Specification for ancillary components for masonry - Part 2: Lintels
- Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics
Source: EU Single Market Compliance Space (SMCS), retrieved 2026-06-23.
https://webgate.ec.europa.eu/single-market-compliance-space/notified-bodies/free-search?text=2337
https://webgate.ec.europa.eu/single-market-compliance-space/notified-bodies/free-search?text=2337
This page is an informational mirror of the official register. It is not affiliated with the European Commission. Always verify the current designation and scope against the official SMCS record before relying on it.